Railway Cables | ||||||||||||
1.8/3KV Single Core Medium Wall Fire Resistant Traction
Cables
Application
Single Core power and control cable designed for protected, fi xed installation inside and outside railway vehicles for connecting fi xed and moving parts.
Standards
● BS 6853 -1a
● DIN 5510-1 1-4
● NFF 16-101 F0
● BS 6387
Construction
Conductors
Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.
Flame Barrier
Mica tape.
Insulation
Electron beam crosslinkable medium wall LSZH compound.
Sheath
Electron beam crosslinkable LSZH compound.
Electrical Characteristics at 20℃
Nominal Conductor Cross Section | mm² |
1.0 |
1.5 |
2.5 |
4.0 |
6.0 |
10 |
16 |
Maximum Conductor Resistance | Ω/km |
20.0 |
13.7 |
8.21 |
5.09 |
3.39 |
1.95 |
1.24 |
Voltage Rating | KV |
1.8/3 |
Nominal Conductor Cross Section | mm² |
25 |
35 |
50 |
70 |
95 |
150 |
Maximum Conductor Resistance | Ω/km |
0.795 |
0.565 |
0.393 |
0.277 |
0.21 |
0.132 |
Voltage Rating | KV |
1.8/3 |
Mechanical and Thermal Properties
Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)
Temperature Range:-40℃ to +120℃
Dimensions And Weight
Cable Code |
No. of cores& Nominal Conductor Cross Sectional Area No. x AWG |
Nominal Diameter of Strands No/mm |
Nominal Insulation Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight |
FRA-MW-3S-FR-1G1.5 |
1×1.5 |
30/0.25 |
0.8 |
3.7 |
26 |
FRA-MW-3S-FR-1G2.5 |
1×2.5 |
50/0.25 |
0.75 |
3.95 |
35 |
FRA-MW-3S-FR-1G4 |
1×4 |
56/0.3 |
0.95 |
4.95 |
55 |
FRA-MW-3S-FR-1G6 |
1×6 |
84/0.3 |
0.90 |
5.35 |
75 |
FRA-MW-3S-FR-1G10 |
1×10 |
80/0.4 |
1.05 |
6.80 |
130 |
FRA-MW-3S-FR-1G16 |
1×16 |
126/0.4 |
1.20 |
8.60 |
190 |
FRA-MW-3S-FR-1G25 |
1×25 |
196/0.4 |
1.35 |
10.2 |
280 |
FRA-MW-3S-FR-1G35 |
1×35 |
276/0.4 |
1.55 |
11.7 |
390 |
FRA-MW-3S-FR-1G50 |
1×50 |
396/0.4 |
1.85 |
13.8 |
550 |
FRA-MW-3S-FR-1G70 |
1×70 |
360/0.5 |
1.70 |
15.8 |
720 |
FRA-MW-3S-FR-1G95 |
1×95 |
475/0.5 |
1.90 |
17.6 |
960 |
FRA-MW-3S-FR-1G120 |
1×120 |
|
1.95 |
20.2 |
1180 |